Model No. JL-240X JL-240Y JL-240Z14
Applicable Volt Range 0~480VAC
Rated Frequency 50/60Hz
Power Loading AWG#14: 15Amp max. / AWG#16: 10Amp max.
Optional Signal Loading AWG#18: 30VDC, 0.25Amp max.
Ambient Temperature -40℃ ~ +70℃
Overall Dimensions (mm) 65Dia.x 40 65Dia.x 67
Accessory Rear Cover ● R option ● R option
Spring Holder - -

Wall mount

Back Cover

- -
Lock Nut - -
Wall Mount Bracket - -

30x(70+130)

Leads 6” Min. (See Ordering Information)
 

Installation

Disconnect power; wire the receptacle according to the diagram below. An arrow indicating NORTH on the top of the receptacle is used to assist correct direction. Push the photocontrol on and turn it clockwise to lock into the receptacle. 

Adjust the receptacle position if necessary. 

JL-240Y series supports tool-free rotation.

JL-240Z series supports Wall-mount and rotation.


Initial Testing

It is normal for the SWITCH to take several minutes to turn off when first installed.

To test “turn on” during daytime, cover its eye with sliding the metal strip mounted.

Do not cover with finger because light traveling through fingers may be great enough to keep the switch open.

Test will take approximately 2 minutes.