The photoelectric switch JL-423C is applicable to control the street lighting, passage lighting and doorway lighting automatically in accordance with the ambient lighting level.
This product is designed with electronic circuits with MCU incorporated. Its quicker response with time delay of 5 seconds offers easy-to-test feature while avoiding mis-operation due to spotlight or lightening during night time. Especially, model JL-423C provides a wide voltage range for customer applications under almost power supplies.
Further, JL-423C-M provides surge protection feature up to 460J/10kA.
Technical Data
Model No. | JL-423C/423CM |
Rated Voltage | 120-277VAC |
Rated Frequency | 50/60Hz |
Rated Loading |
1000W Tungsten 1200VA Ballast@120VAC 1800VA Ballast@208-277VAC 8A e-Ballast@120VAC / 5A e-Ballast@208~277V |
Power consumption | 0.4W max |
Operate Level |
16Lx On 24Lx Off |
Ambient Temperature | -30℃ ~ +70℃ |
IP Grade | IP65 |
Overall Dimensions |
JL-423C: 54.5(L) x 29(W) x 44(H)mm JL-423CM: 54.5(L) x 29(W) x 50(H)mm |
Leads Length | 180mm or Customer request (AWG#16) |
Fail Mode | Fail-On |
Sensor Type | IR-Filtered Phototransistor |
Midnight Schedule | Available per client’s request |
Installation
Disconnect power, remove junction box cover, place the SWITCH in knockout hole and fasten with locknut.
Wire according to the diagram in right hand.
Do not install the switch with the Photocell facing artificial or reflected light. This will cause the unit to cycle on and off at night.
Initial Testing
It is normal for the SWITCH to take several minutes to turn off when first installed.
To test “turn on” during daytime, cover its eye with sliding the metal strip mounted.
Do not cover with finger because light traveling through fingers may be great enough to keep the switch open.
Test will take approximately 2 minutes.